Two-storey extension plans in Greenford cost £645 drawings + £250 survey (£895 total) with our complete planning drawing service. That fixed fee covers the measured survey, existing and proposed drawings, the application pack and submission to Ealing Council. Ealing's householder fee of £548 is paid to the council and shown separately.
On this page
- How does Ealing want a two-storey side extension to look?
- Why does the roof matter so much on a Greenford semi?
- What about a two-storey rear extension?
- Is Greenford in a conservation area?
- What if I plan to let rooms?
- What do two-storey extension plans in Greenford cost from survey to build set?
- Frequently asked questions
Greenford grew between the wars. Ealing's draft Local Plan says the town "developed during the inter-war period" and that suburban semis and suburban terraces make up over half its housing (Ealing Local Plan, Greenford chapter). When a 1930s semi gains a room over the side or the back, a two-storey side extension always needs a planning application.
How does Ealing want a two-storey side extension to look?
Ealing wants a Greenford two-storey side extension set back and set in at least 1 metre at first floor, front and side, with a roof like the main house. Ealing's SPD 4 on residential extensions is still used as guidance. It says two-storey extensions "are not encouraged", but where you build one it sets clear tests (Ealing SPD 4):
- Front set-back. The front wall should be set back at least 1 metre from the front of the house at first floor and above.
- Side gap. It should be set in at least 1 metre from the side boundary at first floor.
- Roof. Generally the same pitch as the main roof, with the same eaves detail, and "flat roofs are not normally appropriate for two-storey extensions".
- Scale. It should look subordinate to the house.
The 1 metre gap at first floor decides whether a Greenford plot works. Where a side passage is not much more than 2 metres wide, a first floor set in by 1 metre leaves a narrow room. Our survey measures the passage first, and we tell you whether the room is worth having before you pay for the full design.
Why does the roof matter so much on a Greenford semi?
On a Greenford semi the roof is where Ealing's newer guidance is firmest. The Housing Design Guidance of November 2022 has a section on "suburban semi-detached and terrace blocks", which it says are found in Southall, Greenford and Perivale. For that house type it says "flat roofs in side or vertical extensions are unacceptable, with hipped or gable roofs a more resolved form" (Ealing Housing Design Guidance).
The same guidance says side extensions should be subordinate and step back from the building line. For lofts in semis it says: "For hipped roofs, avoid changing this to a gable roof if a hipped roof remains next door." Where your semi and its pair have a hipped roof, a two-storey side extension carries a hip of its own, set lower than the main ridge.

What about a two-storey rear extension?
A two-storey rear extension on a semi is judged mainly on the attached neighbour. SPD 4 says two-storey rear extensions "can be contentious", and that on semis and terraces they can dominate the views from the neighbour's ground-floor windows and garden. It asks for them to be subordinate and, where possible, set back from the shared boundary.
The 2022 guidance adds two general tests: rear extensions of 3.5 metres are likely to be acceptable as a guide, with more needing "a sound design justification", and massing should follow the 25 and 45 degree rules to avoid overshadowing. We draw the neighbour's nearest window and the 45 degree line on the plan, so the officer sees the test passed.
A two-storey rear extension is permitted development only within 3 metres of the original rear wall, 7 metres from the back boundary, 2 metres from both side boundaries and outside a conservation area (GPDO Class A, A.1(h), A.1(i), A.2(c)); on a semi, the 2 metres from the party wall leaves a narrow strip (GPDO 2015, Schedule 2, Part 1, Class A).
If it passes, the job is building regulations drawings with structural calculations from £1,195, with no planning application; a certificate of lawfulness is optional and separate. Our permitted development checker asks the same questions.
Is Greenford in a conservation area?
Greenford is usually not in a conservation area. Ealing has 30 conservation areas and groups them on its website under Acton, Ealing, Hanwell, Northolt, Southall and NW10, with no Greenford heading (Ealing conservation areas). We still check your address against Ealing's conservation area map before drawing. Outside a conservation area, the tests are the SPD 4 and 2022 guidance rules above, not a heritage judgement, so an application there needs no heritage statement.
That makes the design itself the whole case. The officer will compare your side extension with others on the street, so our elevations show the neighbouring semi and its roof line. Where the pair has already been extended on one side, we draw that too, because the balance of the pair is what the guidance asks you to keep.
What if I plan to let rooms?
Since 14 November 2025, changing a house to a small HMO needs planning permission across Ealing, apart from Perivale and the Old Oak and Park Royal area (Ealing Council). Greenford is covered. If an extension is meant for lettings, say so at the start; our Ealing HMO page explains that application.
What do two-storey extension plans in Greenford cost from survey to build set?
A Greenford two-storey extension costs our planning drawings and Ealing's fee first, then the building regulations stage after the grant:
- Planning drawings and submission: £645 drawings + £250 survey (£895 total).
- Ealing's householder fee: £548, paid to the council.
- After the grant: building regulations drawings at £795 and structural calculations from £425.
- All three booked together at the start: our planning and building regs package from £1,495, which contains the planning drawings and so replaces the first line.
In the year to 30 June 2026 Ealing decided 407 of its 424 householder applications within eight weeks (MHCLG live table PS2).
Consider an imagined case (illustrative, not a real job): a 1930s semi off Oldfield Lane has a 2.6 metre side passage. A two-storey side extension set in 1 metre at first floor leaves a first-floor room 1.6 metres wide, too narrow for a bedroom. Keeping the ground floor full width and putting the extra bedroom in a first-floor rear extension may give more room, either under permitted development if it can stand 2 metres off both side boundaries, or by application under the 3.5 metre and 45 degree tests. We would draw both before you choose.
For the borough, see our Ealing page and Ealing house extensions, or nearby guides on Hanwell planning drawings and Southall extensions.
Work out your fee
FFP-01 · Rev AHouseholder application fee, paid to your council at submission.
Prices include one measured survey of a house of up to two storeys (£250). A flat or maisonette is £50 less; a house of three storeys or more is £50 more. One survey covers every service on the same job.
Plus the Planning Portal's own charge if the application goes through the Portal: up to £149 including VAT, depending on the application type, and some types have none (source).
Get this fee in writingor email hello@fixedfeeplans.co.uk
No obligation. Nothing is sent until you ask; your enquiry comes to us and nowhere else.
Frequently asked questions
Do I need planning permission for a two-storey side extension in Greenford? Yes. Side extensions of more than one storey are not permitted development, so Ealing needs an application drawn to SPD 4's set-backs.
Can a two-storey side extension in Greenford have a flat roof? Unlikely. SPD 4 says flat roofs are not normally appropriate for two-storey extensions, and Ealing's 2022 guidance calls flat roofs on side extensions to suburban semis unacceptable.
How far from the boundary must the first floor be? SPD 4 asks for at least 1 metre from the side boundary at first floor, and a set-back of at least 1 metre from the front wall.
If the application goes through the Planning Portal, the Portal adds its own service charge: nothing, £99 or £149 including VAT, depending on the application type and complexity, paid to the Portal at submission and not normally refunded with a council fee (Ashford Borough Council, Planning Portal service charges, 11 September 2026). It is not ours and not the council's. Other submission routes exist; where your council accepts one without a charge, we can use it.






